Motor Driver(5-Phase stepper motor driver)
SDL-5862/SDL-5602/SDL-5422
■ Features
● DC24V(Available 18 to 32VDC of power supply range)
● Setting of phase current 0.2A-0.75A for SDL-5422
● Setting of phase current 0.4A-1.4A for SDL-5602and SDL-5862
● Setting of micro-step interpolation from 1 to 20
● Built-in stop/run current adjustment function.
● Bipolar constant current pentagon driver method
Naming Rule
Model |
SDL-5862/SDL-5602/SDL-5422 |
|
Power supply※1 |
18-32VDC |
|
RUN current |
0.2A-0.75A for SDL-5422 0.4A-1.4A for SDL-5602 and SDL-5862 |
|
RUN method |
Bipolar constant pentagon drive |
|
Basic step angle |
0.72.°/Phase |
|
Resolution |
1,2,4,5,8,10,16,20 division (0.72°to 0.036°) |
|
Input pulse width |
Min. 0.2μs |
|
Pulse Duty |
50% |
|
Rising/Falling time |
Max. 120ns |
|
Max. input pulse frequency※2 |
1MHz |
|
Input voltage Level |
High: 4-5VDC , Low: 0-0.5VDC |
|
Input resistance |
330330Ω (PUL/CW, DIR/CCW, HO) |
|
Environ- ment |
Ambient temperature |
0℃ to +65℃ , Storage: -10℃ to +55℃ |
Ambient humidity |
35 to 85%RH Storage: -10 to 90%RH |
|
Unit Weight |
140g |
※ ※When using over 30VDC,it should be mounted at ventilated place due to
increasing heat.
※ ※Max. pull-out frequency and max. slewing frequency are variable,
depending on resolution, or load.
※Environment resistance is rated at no freezing of condensation
■ Setting microstep
Division Switch |
Setting microstep |
Resolution |
Step angle |
||
|
SC |
SB |
SA |
|
0.72° |
ON |
ON |
ON |
1/1 |
0.72° |
|
ON |
ON |
OFF |
1/2 |
0.36° |
|
ON |
OFF |
ON |
1/4 |
0.18°
|
|
ON |
OFF |
OFF |
1/5 |
0.144° |
|
OFF |
ON |
ON |
1/8 |
0.09° |
|
OFF |
ON |
OFF |
1/10 |
0.072° |
|
OFF |
OFF |
ON |
1/16 |
0.045° |
|
OFF |
OFF |
OFF |
1/20 |
0.036° |
※ Microstep is to make basic step angle of 5-phase
※ Motors(0.72°)divided into smaller angle according to setting values.
※ ※ The formula for microstep angle is:
Motor revolution angle(5-phase motor)=Basic step angle(0.72°)/Resolution
※ In case of geared motor, step angle shall be determined by dividing
step angle by gear ratio EX)0.72°/10(1:10)=0.072°
※ Resolution is not allowed to be changed While Motor is running.
Applications:
Industrial Robots
Manipulators
Automation
Alignment Stage
Positioning Stage