Brake unit SD800
Features
Novel structure design; Complete upgrade of the software; Optimized production technique; Mature test equipment.
1. For all brands inverter;
2.200V/380V/440V/480V;
3. It could be paralleled connected, no capacity limited;
4. Allowable for the occasion with electricity fluctuation;
5. Special design, the ordinary resistor could be used so no need to use senseless resistor. Resistor box could be specially ordered;
6. Ensure the brake IGBT in saturation;
7. Protection: Short-circuit, low voltage, over voltage, fast fuse, over heated;
8. Automatic track during the whole process;
9. Noise filtrated within all frequency range, no disturbance to other equipment
Power |
Voltage |
Phase |
0.75kw~1.5kw |
220v~240v |
single phase input & 3 phase output |
0.75kw~7.5kw |
220v~240v |
single phase input & 3 phase output |
0.75kw~5.5kw |
220v~240v |
3 phase input& 3 phase output |
7.5kw~630kw |
220v~690v |
3 phase input& 3 phase output |
0.75kw~630kw |
380v~690v |
3 phase input& 3 phase output |
Specifications
Items |
Specifications |
||
Power |
Voltage and frequency |
Single-phase 200~240V, 50/60Hz Three-phase 200~240V, 50/60Hz Three-phase 380~415V, 50/60Hz Three-phase 440~460V, 50/60Hz Three-phase 575V, 50/60Hz Three-phase 660V, 50/60Hz Three-phase 1140V, 50/60H |
|
Allowable Fluctuation range |
Voltage: ± 15% Frequency: ± 5% |
||
Control |
Control system |
High performance vector control inverter based on DSP |
|
Output frequency |
G/F/Z/S/T/M: 0.00~400.0Hz, the maximum frequency range is 10.00~320.0Hz |
||
Control method |
V/F control, V/F+ PG control, vector + PG control |
||
Waveform produce methods |
asynchronous space vector PWM, step less and subsection synchronous space vector PWM, 2 phase optimized vector PWM |
||
Auto torque boost function |
Realize low frequency (1Hz) and large output torque control under the v/f control mode. |
||
Accelerate /decelerate control |
Acceleration/Deceleration S curve subsection set mode. The maximum running time is 26 hours. |
||
Program running control |
7 step speed program running, the maximum running time is 88 hours. |
||
Frequency setting accuracy |
Digital references: 0.01Hz(300 Hz and below), 0.1 Hz(above 300 Hz) Analog references: 0.05Hz/60Hz |
||
Frequency accuracy |
Speed control tolerance 0.01%(25± 10) |
||
V/F curve mode |
Linear, square, 8 V/F curve set by user |
||
Over load capability |
G/S: 150% for one minute, 200% for 0.1 second F: 120% for one minute, 150% for 0.1 second Z/M/T: 180% for one minute, 250% for 0.1 second H: 250% for one minute, 300% for 0.1 second |
||
Slip compensation |
0~10% automatic slip compensation |
||
Running |
Input signal |
Running method |
Keypad/Terminal/Communication mode |
Frequency setting |
There are 11 frequency setting modes, including DC 0~10V, DC 0~20mA, DC 4~20mA, potentiometer on the keyboard. |
||
Start signal |
forward, reverse |
||
Multi-segment speed |
can set 7 steps speed at most(using multi-function or program running) |
||
Multi-segment acceleration |
At most 8 steps acceleration can be set (using multi-function terminals or program running. ) |
||
Instant stop |
Interrupt controller' s output. |
||
Traverse running |
Program control running |
||
Jog |
running in low speed |
||
Fault reset |
When the protection function is affective, system can reset fault state automatically. |
||
PID feedback signal |
DC 0~10V, DC 1~5V, DC 0~20mA, DC 4~20mA |
||
Running |
Output signal |
Running state |
motor state display, stop, accelerate/decelerate, seven-speed, program running state |
Fault output |
relay fault output: AC 250V 5A, DC 30V 5A |
||
Analog output |
2 analog output, 8 signals could be selected: frequency, current, voltage, temperature, etc, the output signal range is 0~10V/0~20Ma. |
||
Output signal |
6 output signals, each one with 32 signals for option. |
||
Running function |
Limit frequency, skip frequency, torque difference compensate, reverse protection, automatic adjustment, PID control |
||
DC brake |
On base of non-OC, internal PID can regulate braking current to ensure enough braking torque. |
||
Protection function |
Inverter protection |
Over voltage, under voltage, over current, over load, overheat, over current stall, over voltage stall, phase loss (options), external fault, communication fault, PID feedback abnormity, PG fault. |
|
IGBT temperature display |
Display of current IGBT temperature |
||
Inverter fan control |
Temperature of starting the fan can be set. (options) |
||
Restart after momentary power loss |
less than 15ms: continue running More than 15ms: automatic inspection of motor' s speed, restart after transient power down. |
||
Speed starting pursue mode |
inverter pursue motor speed automatically before starting |
||
Parameter protection function |
protect inverter' s parameter by setting password and decode |
||
Communication |
RS485 |
Completely isolated RS485 communication module (options), realizes the communication with the host computer. |
|
CAN BUS |
CAN BUS module(options) |
||
Environment |
Environment temperature |
-10 ~ 40 |
|
Storage temperature |
-20 ~65 |
||
Environment humidity |
Less than 90 % RH |
||
Height / libration |
less than 1, 000 m, less than 5.9m/s 2 (=0.6g) |
||
Application place |
where there is no rust gas, no flammability gas, no grease and dust |
||
Cooling methods |
Forced air cooling and natural cooling |
Applications
Mechanics, electronics, metallurgy, mining, petrochemical, transportation, building materials, municipal, metal processing, textile, printing and dyeing, paper making, Injection machine, central air conditioning, numerical control machine tool, air-compressor, fan and pump, blower, air conditioner for large buildings; Waste water treatment system; Water supply system for large buildings; Public water supply system and other industries and fields.